Email alerts failing to send from Dell iDRAC v9

From Peter Pap's Technowiki
Revision as of 05:35, 8 October 2020 by Ppapa (talk | contribs) (Created page with "If you have a Dell server with a version 9 iDRAC, release 4.x, you'll no doubt no longer be receiving email from it. The reason for this is: ''After iDRAC is upgraded to ver...")

(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

If you have a Dell server with a version 9 iDRAC, release 4.x, you'll no doubt no longer be receiving email from it. The reason for this is:

After iDRAC is upgraded to version 4.00.00.00, you may stop receiving encrypted email alerts from iDRAC, if the external email server does not support encryption. iDRAC firmware version 4.00.00.00 introduces a user-selectable encryption option and the default protocol is StartTLS.


To start receiving email messages again, disable the email encryption by using the following RACADM command:

racadm set idrac.RemoteHosts.ConnectionEncryption None